Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters

Database
Language
Document Type
Year range
1.
Environ Sci Eur ; 35(1): 34, 2023.
Article in English | MEDLINE | ID: covidwho-2314423

ABSTRACT

Background: COVID-19 pandemic is not yet over, and it has been generating lots of plastic wastes that become a big concern. To catch the virus, for example, no matter via antigen or PCR test, swab is generally used for sampling. Unfortunately, the swab tip is commonly made of plastics, and thus it can be a potential source of microplastics. This study aims to propose and optimise several Raman imaging to identify the microplastic fibres released from different COVID-19 test swabs. Results: The results show that Raman imaging can effectively identify and visualise the microplastic fibres released from the swabs. In the meantime, on the surface of the fibres, additives such as titanium oxide particles are also captured for some brands of swabs. To increase the result certainty, scanning electron microscope (SEM) is first employed to get the morphology of the released microplastic fibres, along with Energy-dispersive X-ray spectroscopy (EDS) to confirm the presence of titanium element. Then, Raman imaging is advanced to identify and visualise the microplastics and titanium oxide particles, from different characteristic peaks in the scanning spectrum matrix. To further increase the imaging certainty, these images can be merged and cross-checked using algorithms, or the raw data from the scanning spectrum matrix can be analysed and decoded via chemometrics, such as principal component analysis (PCA). Beyond the advantages, the disadvantages of the confocal Raman imaging (affected by focal height) and algorithms (non-supervised calculation) are also discussed and intentionally corrected. In brief, the imaging analysis (particularly the combined SEM with Raman) is recommended to avoid the possible result bias that might be generated from the single spectrum analysis at a selective but random position. Conclusions: Overall, the results indicate that Raman imaging can be a useful tool to detect microplastics. The results also send us a strong warning that, if we worry about the potential microplastics contamination, we should be cautious to select the suitable COVID-19 testing kits. Supplementary Information: The online version contains supplementary material available at 10.1186/s12302-023-00737-0.

2.
Curr Pharm Des ; 28(18): 1445-1456, 2022.
Article in English | MEDLINE | ID: covidwho-2278122

ABSTRACT

The analytical investigation of the pharmaceutical process monitors the critical process parameters of the drug, beginning from its development until marketing and post-marketing, and appropriate corrective action can be taken to change the pharmaceutical design at any stage of the process. Advanced analytical methods, such as Raman spectroscopy, are particularly suitable for use in the field of drug analysis, especially for qualitative and quantitative work, due to the advantages of simple sample preparation, fast, non-destructive analysis speed and effective avoidance of moisture interference. Advanced Raman imaging techniques have gradually become a powerful alternative method for monitoring changes in polymorph distribution and active pharmaceutical ingredient distribution in drug processing and pharmacokinetics. Surface-enhanced Raman spectroscopy (SERS) has also solved the inherent insensitivity and fluorescence problems of Raman, which has made good progress in the field of illegal drug analysis. This review summarizes the application of Raman spectroscopy and imaging technology, which are used in the qualitative and quantitative analysis of solid tablets, quality control of the production process, drug crystal analysis, illegal drug analysis, and monitoring of drug dissolution and release in the field of drug analysis in recent years.


Subject(s)
Illicit Drugs , Spectrum Analysis, Raman , Chemistry, Pharmaceutical/methods , Humans , Pharmaceutical Preparations , Quality Control , Spectrum Analysis, Raman/methods , Tablets/chemistry , Technology, Pharmaceutical/methods
3.
J Hazard Mater ; 439: 129621, 2022 10 05.
Article in English | MEDLINE | ID: covidwho-1936775

ABSTRACT

Due to COVID-19, large amounts of personal protective equipment (PPE) have been used, and many PPE units are made of plastics, such as face masks. The masks can be burned naturally in a bushfire or artificially at the incineration plants, and release microplastics and nanoplastics from the mask plastic fibres. A fire can cause the plastic, such as polypropylene (PP) fibres, to be molten and stick to the solid surface, such as glass, soil, concrete or plant, as films or islands, due to the binding property of the molten plastic material. Once the films or islands are peeled off in the processes such as weathering, ageing, or treatment and clean-up, there are residuals leftover, which are identified as nanoplastics and microplastics via Raman imaging, with the significant release amount of ~1100 nanoplastics / 10 µm2 or ~11 billion / cm2, and ~50 microplastics / 420 µm2 or ~12 million / cm2. Moreover, surface group is deviated on the plastic surface, which can also be distinguished and visualised as well via Raman imaging, down to nano size. This test validates the Raman imaging approach to capture microplastics and nanoplastics, and also provides important information about the fate and transportation of PPE mask in the environment, particularly when subjected to a fire. Overall, Raman imaging can be an effective option to characterise the microplastics and nanoplastics, along with the deviated surface group.


Subject(s)
COVID-19 , Water Pollutants, Chemical , COVID-19/prevention & control , Humans , Microplastics , Personal Protective Equipment , Plastics/chemistry , Water Pollutants, Chemical/analysis
SELECTION OF CITATIONS
SEARCH DETAIL